• TwitterFacebookGoogle PlusLinkedInRSS FeedEmail

Pyronix Belle Installation Manual

5/26/2019 
Environmental Class IV

View and Download Pyronix Sterling 10 installation manual online. Control Panel with Remote Keypads. Sterling 10 Control Panel pdf manual download.

• Latest artistic floor and grain effects. How To Activate Magic Bullet Suite 13 Crack License Key: Download Red Giant Magic Bullet Suite 13 Crack Patch Activator With Key Code from given below link. • Virus threats fixes and a few modifications. Follow given instructions in readme text file to activate. Magic bullet denoiser 2 free download

  • Security Sensors Pyronix KX10DP Installation Manual. 10m digital pet pir detector (4 pages) Security Sensors Pyronix KX15DD Manual. 15m digital pir detector (4 pages) Security Sensors Pyronix KX15DT Manual. 15m dual-technology detector (4 pages) Security Sensors Pyronix XDL15TT-AM Installation Manual.
  • Pyronix Sterling 10 Manual Online: Belle Connections. SPEAKERVOLUME R- +R TUFSMJOH10 Z1Z2 Z3+AUX– Z4Z5 +AUX–Z6 Z7Z8 TT BELLENOTE: Ensure.
10.525GHz
BE CH CY DK HU IE IS
IT MT NL NO SE SI
10.587GHz
E N G L I S H
Anti-Masking: The XDH10TT-AM uses the patented Anti-Masking
technology to detect when one or both PIR detectors as well as the
The detector is able to detect aluminium foil, spray and any object position
on or in front of the detector with the purpose of obstructing the field of
The masking area is adjustable between 0 to 1M.
If the masking area is entered the Blue LED starts flashing to show that
the area has been compromised. If the obstacle is removed after 30 seconds
and the BLUE alarm LED have activated the detector will reset to normal. If
the obstacle still remains after 1 minute, the MASK and ALARM relay will open
and the Green and Orange LEDs will be permanently activated. To reset the
detector, the obstacle must be removed and a walk test should be done.
The Anti-Masking can be disabled when the panel is armed. For this the RI
terminal has to be connected to an output of the panel which is POSITIVE
when ARMED. To enable this feature also, switches 2 and 4 must be OFF.
Blocking: This feature allows the detection of obstruction located at 10M
or less and is used when the panel is disarmed. When the blocking feature is
active the Alarm relay will open and the Green and Orange LEDs will be
activated. To reset the blocking XD should be walk tested so that both PIRs
To enable the feature, switches 3 and 4 must be OFF and the RI input
should be connected to an output on the control panel which gives a
Technical Specification
Casing: 3mm polycarbonate, 0.4mm HDPE in Lens Area
Tri-Detection Method: 2 low noise dual element passive infrared sensors
Tri-Masking Adjustable: from 0M to 1M. Covers all 3 technologies.
Temperature Compensation: Digital
Operating Voltage: 9-16VDC, 13.8VDC typically
Relay Output: 3 x SELV limits, 60VDC 50mA (42.4VAC peak)
Mounting Height & Range: 1.8M - 2.4M = 10M (Lens 5)
Tamper Switch: 12VDC 50mA both front and rear
Storage Temperature: -40°C to +80°C (+40°F to 176°F)
Operating Temperature: -30°C to +70°C (+22°F to 158°F)
Emissions EN55022 Class 2.
Warranty
This product is sold subject to our standard warranty conditions and is
warranted against defects in workmanship for a period of five years
(excluding lens). In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserves the right to amend
Product Warning Information
For electrical products sold within the European Community. At the end of
the electrical products life, it should not be disposed of with household
waste. Please recycle where facilities exist. Check with your Local Authority
Optional Accessories
XD-FIXEDBRACKET + Fixed Lens Mask
Frequency
This product operates in a European non-harmonized frequency band.
Hereby, Pyronix, declares that this XDH10TT-AM is in compliance with the
essential requirements and other relevant provisions of Directive
1999/5/EC. The declaration of conformity may be consulted at
 0845 6434 999 (UK). +44(0)1709 535 225
3
3k
12k
6k8
EOL
EOL R1
EOL
TAMPER
TAMPER
1k
10k
6k8
5k6
4k7
2k7
2k2
1k5
A
T
1k5
+12V 0V
1k
PCX 46
MAX
≤1m
W = XD-WALLBRACKET
MASK/ALARM LINK
DEOL
3k
12k
6k8
EOL
LED ALARM N/O
EOL
4k7
TAMPER
2k2
10k
5k6
4k7
3k9
3k9
2k7
2k2
A
T
A
T
1k5
+12V 0V
1k
820R
PCX 46
30% Mask
>1m
2
3k
12k
6k8
LED ALARM N/O
EOL
EOL R1
ALARM N/O
TAMPER
1k
10k
5k6
6k8
5k6
3k9
4k7
2k7
2k7
2k7
2k2
A
T
+12V 0V
1k5
EOL INPUT 1 COM
1k
820R
EOL
EOL R1
ALARM N/C MASK/FAULT
PCX 46
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
ATE INPUTS
Pyronix Belle Installation Manual
N/C
3k
15k
12k
8k2
6k8
5k6
EOL
EOL R1
4k7
ALARM N/C MASK/FAULT
2k2
1k
10k
5k6
6k8
5k6
3k9
4k7
3k9
2k2
2k7
2k2
1k
A
T
1k5
EOL INPUT 1 COM
820R
3k
12k
6k8
4k7
1k
10k
5k6
4k7
4k7
3k9
2k2
1k5
Pyronix Belle Installation Manual
1k5
1k
No resistors are required for

Advertisement

Related Manuals for Pyronix XDH10TTAM

  • Security Sensors Pyronix KX15DD Manual
    15m digital pir detector (4 pages)
  • Security Sensors Pyronix KX15DC-WE Manual
    15m digital curtain wireless pir (2 pages)

Summary of Contents for Pyronix XDH10TTAM

  • Page 1 This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of five years (excluding lens). In the interest of continuing improvement of quality, customer care and design, Pyronix Ltd reserves the right to amend Max: 1M 30% Mask specifications, without prior notice.
  • Page 2 50Hz 60Hz EOL INPUT 1 COM NO C NC Usc. PGM [0022] PCX 46 Ogni Area Inst.  0845 6434 999 (UK). +44(0)1709 535 225  customer.support@pyronix.com  www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK..
  • Page 3 Do not partially or Alarm completely obscure the detector’s eld of view BOTTOM PIR with large objects Mask Processing  0845 6434 999 (UK). +44(0)1709 535 225  customer.support@pyronix.com  www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK..
  • Page 4 The following languages are available online via the QR code: Bulgarian, Czech, Danish, German, Greek, Spanish, Finnish, French, Croatian, Hungarian, Italian, Dutch, Norwegian, Polish, Portuguese, Romanian, Russian, Slovak, Slovenian, Serbian, Swedish  0845 6434 999 (UK). +44(0)1709 535 225  customer.support@pyronix.com  www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK..
  • Page 5 è conforme ai requisiti essenziali e tutte le ulteriori frecuencias en la parte superior de la sección del texto). Por medio del presente le tableau des fréquences au début de cette section de texte). Pyronix déclare par la disposizioni pertinenti la direttiva 1999/5/CE. La dichiarazione di conformità può..
  • Page 6 Данное изделие работает в европейской негармонизированной полосе частот (см. таблицу tabela częstotliwości u góry tej części tekstu). Firma Pyronix niniejszym deklaruje, (ver tabela de frequência no início desta secção de texto). Pelo presente, a Pyronix частот в начале этого раздела). Настоящим Pyronix заявляет, что извещатель XDH10TT-AM że urządzenie XDH10TT-AM jest zgodne z zasadniczymi wymaganiami i innymi..